YATO YT-73093 600A AC/DC TRUE RMS CLAMP METER
Brand: Yato
Part No: YT-73093
Item Description: Clamp Meter
Display Type: LCD
Display Range: 6000
LED Backlight: Yes
Bell Ring: Yes
Auto Measurement Range: Yes
Auto Power off: 15 Min
Condition: New
₦113,482.00
Brand: Yato
Part No: YT-73093
Item Description: Clamp Meter
Series: GRF
Alternating Voltage: 0-600 V a.c.
Direct Voltage: 0-600 V d.c.
Alternating Current: 0-600 A
Direct Current: 0-600 A
Resistance: 0-60 MΩ
Capacity Measurement: 0-60 mF
Frequency Measurement: 0-10 MHz
Temperature: -30 ~ +1000 ˚C
Continuity Test: 0-50 Ω
Conduction Test: Yes
Diode Test: Yes
Battery Test: Yes
Peak Measured Vlue Preservation Mode: Yes
Non-Contact AC Voltage Detection NCV: Yes
Dimensions: 172x64x32 mm
Material: ABS
Max. Clamp Gap: 25 mm
Max. Diameter Of The Tested Cable Using The Clamp: 25 mm
Display Type: LCD
Display Range: 6000
LED Backlight: Yes
Bell Ring: Yes
Auto Measurement Range: Yes
Auto Power off: 15 Min
Data Hold: Yes
Sampling Frequency: 3 Times Per Second
TRUE RMS: Yes
Front Lighting: Yes
Power Supply: Battery
Type Of Battery: 2×1.5V; AAA
Low Battery Indicator: Yes
Working Temperature Range: 0~40 ˚C
Operating Relative Humidity Rh: < 75 %
Storage Temperature: -10 ~ +50 ˚C
Weight: 0.161 kg
Application: ElectricFeatures:
The Universal YT-73093 Cruise Meter With An Automatic Range For Each Measurement Enables Basic And Advanced Electrical Measurements. The Meter Has Been Equipped With Measuring Pitches, Which Allow For Measuring DC And AC In A Single Cable Using A Built -In Hall Sensor. The Measurement Takes Place Without The Need To Disconnect The Circuit Or Disconnect It From The Power Source And Allows You To Measure A Much Higher Current Intensity Than In The Case Of Conventional Electrical Meters. Basic Measurements Measurement Of Alternating Voltage: A.C. 0-600V, TRUE RMS MEASUREMENT OF DC voltage: D.C. 0-600V ACTION MEASUREMENT: A.C. 0-600A, TRUE RMS DC Measurement: D.C. 0-600A Resistance Measurement: 0-60MΩ LED Test: IF 5MA, UR 3V Circumference Continuity Test: 0-50Ω Additional Measurements Capacitor Capacity Measurements: 0-60mf Frequency Measurement: 0-10MHz Temperature Measurement: -30 to 1000 ° C Non-Contact Detection Alternating Voltage: NCV Measurement Accuracy Example Of Determining Accuracy For Measuring AC Alternating Current. Calculations For The Measurement Result: 30A Measurement Accuracy Of The YT-73093 Meter For This Range Is: ± (2.0% + 30), Resolution 0.01a Measurement Error Calculation Pattern: (Measurement Result x 2%) + 30 x Calculation Resolution: (30 x 2 %) + 30 x 0.01 = 0.6 + 0.3 = 0.90A The Actual Result, Taking Into Account The Measuring Error For The Indication 30a = 30 ± 0.90a. & Nbsp; The Result, Taking Into Account The Measuring Error For Indicating The Measurement Of Alternating Voltage: 235V = 235 ± 4.175V, The Result Taking Into Account The Measuring Error For Indicating The Measurement Of A Fixed Voltage: 12V = 12 ± 0.09V The Table With Resolution And Accuracy For A Given Measurement Is In The User Manual. Built -In TRUE RMS Functions - A Meter With This Function Calculates The Real Value Of The Effective Value Of Alternating Current And Intensity For Both Sinusoidal And Non -Sinusoidal Mileage. The Device First Measures The Actual Sinusoid Value At Several Intervals → Then The Measurement Results Are Raised To A Square → Sums Them In The Average → Calculates → And Finally The Average Element. The Measurement Result Is A Real Effective Value Of Alternating Current Voltage/Current Even For A Deformed Sinusoid Or Rectangular NCV Mileage - Non -Contact Alternating Voltage Detection Using The Induction Method. The Meter Detects The Presence Of Measuring Unknown Values Using A Meter With A Manual Change In The Range Using The Knob, Measurements Should Be Made Successively From The Largest Range To The Range That Gives The Most Accurate Result - Otherwise We Risk Damage To The Device. However, In The Case Of A Multimeter with a car function, you just need to make one measurement and the meter will automatically find the optimal range. The meter is launched by default in the Auto Data Hold mode - behavior on the display of the currently measured Peak Hold - behavior on the display of the highest measured value using Inrush Current measuring probes - starting current measurement using measuring tips. The meter will measure the current intensity within 100ms of starting the device Additional information LCD display, & nbsp Diode test) A sound signal in the circuit continuity test below 50Ω CHYS DISPLEMS to 25 mm and allows measuring a single cable with a maximum of up to 25 mm measuring probe with a length of 14.5 cm long cable length along with probes: 97 cm Diameter of the cable along with Insulation: 3.5 mm The set is included in the design cover with overload protections. Automatic switching off the meter after 15 minutes of inactivity. Possibility to turn off the automatic switching mode of the device low battery level. Power supply: two 1.5V batteries (AAA) NOTE. It is performed only on a single vein, a single wire. Fastening of the fibers on a multi -core cable without separating a single vein will show an abnormal result or zero current flow.Condition: New